coil_overwrites:

Config file section

Valid in machine config files NO
Valid in mode config files NO

Some devices offer one or multiple coil_overwrites: settings where you can overwrite coil settings.

Most commonly this is used in flippers: and autofire_coils:.

Optional settings

The following sections are optional in the coil_overwrites: section of your config. (If you don’t include them, the default will be used).

hold_power:

Single value, type: float(0,1). Default: None

Overwrite the hold_power of the coil for this device. See default_hold_power in coils: for details.

pulse_ms:

Single value, type: time string (ms) (Instructions for entering time strings) . Default: None

Overwrite the pulse_ms of the coil for this device. See default_pulse_ms in coils: for details.

pulse_power:

Single value, type: float(0,1). Default: None

Overwrite the pulse_power of the coil for this device. See default_pulse_power in coils: for details.

recycle:

Single value, type: boolean (Yes/No or True/False). Default: None

Overwrite the recycle setting of the coil for this device. See recycle in coils: for details.