lisy:

Config file section

Valid in machine config files YES
Valid in mode config files NO

The lisy: section of your config is where your lisy platform. See How to use MPF with Gottlieb System 1 or 80 machines for details.

Optional settings

The following sections are optional in the lisy: section of your config. (If you don’t include them, the default will be used).

baud:

Single value, type: integer. Default: None

Baudrate when connecting to LISY using a serial port.

connection:

Single value, type: one of the following options: network, serial. Default: network

Whatever to use a network or serial connection.

display_flash_frequency:

Single value, type: number (will be converted to floating point). Default: 1.0

How fast should the displays flash? Defaults to once per second or 1Hz.

network_host:

Single value, type: string. Default: None

Host to connect when connecting to LISY via network.

network_port:

Single value, type: integer. Default: None

Port to connect when connecting to LISY via network.

poll_hz:

Single value, type: integer. Default: 1000

How fast should MPF poll LISY for switch changes? Defaults to 1000Hz

port:

Single value, type: string. Default: None

Serial port when connecting to LISY using serial.