This is the documentation for MPF 0.55+, which is the “dev” (next) release of MPF that is a work-in-progress. Unless you’re specifically looking for this version, you probably want to use the version of documentation called “latest” which is for the latest released version of MPF. That documentation is at docs.missionpinball.org/en/latest.

How to configure switches (P3-ROC)

Related Config File Sections
switches:

To configure switches on a P3-ROC, you can follow the guides and instructions in the Switches docs.

However there are a few things to know about using switches with a P3-ROC.

number:

Unlike the P-ROC, the P3-ROC does not have switch inputs on the P3-ROC itself. Instead, you add SW-16 boards which each have 16 direct switch inputs. (e.g. there is no switch matrix.) You can connect up to 16 SW-16s to support as many as 256 switches.

../../_images/multimorphic_SW-16.png

Each SW-16 has a unique board number which is set using DIP switches (find that out now). On each board there are two banks (A and B) of 8 switches. Then each switch has an input number (0 to 7).

To configure the number: of a switch connected to an SW-16 board and a P3-ROC, you have two options:

Board Bank Switch Syntax

The first (and easier) option is to enter the number as a combination of the SW-16 board address (0-15, as configured by the DIP switches), then the bank number (Bank A is 0, Bank B is 1), then the switch input number (0-7).

For example:

switches:
  my_switch:
    number: A0-B0-0    # SW-16 board at address 0, Bank A, Switch 0
  my_other_switch:
    number: A2-B1-5    # SW-16 board at address 2, Bank B, Switch 5
This example is tested to be valid MPF config. However, it is not integration tested.
switches:
  my_switch:
    number: A0-B0-0    # SW-16 board at address 0, Bank A, Switch 0
  my_other_switch:
    number: A2-B1-5    # SW-16 board at address 2, Bank B, Switch 5

Direct Numbering

You can also use the internal number. As mentioned in the SW-16 manual you can calculate those using:

Bank A switch: P3-ROC switch # = SW-16 address * 16 + Bank A switch input Bank B switch: P3-ROC switch # = SW-16 address * 16 + 8 + Bank B switch input

However, we recommend the above syntax because it will perform this calcuation for you.

For example:

switches:
  my_switch:
    number: 0     # SW-16 board at address 0, Bank A, Switch 0
  my_other_switch:
    number: 45    # SW-16 board at address 2, Bank B, Switch 5
This example is tested to be valid MPF config. However, it is not integration tested.
switches:
  my_switch:
    number: 0     # SW-16 board at address 0, Bank A, Switch 0
  my_other_switch:
    number: 45    # SW-16 board at address 2, Bank B, Switch 5

Connecting Switches

Switches are connected between the input pin and ground. On SW-16 revision 1 those are pins 1, 3-9 for switch 0 to 7 on bank A (J2) and 1, 2, 4-9 for switch 0 to 7 on bank B (J6). Ground is on 10 for both banks. On SW-16 revision 2 those are pins 2 to 9 for switch 0 to 7 and 10 for ground on headers J2 (Bank A) and J6 (Bank B). Revision two has an additional low current 12V output on pin 1.

Burst Switch Inputs

Burst switch inputs (J3 to J10) on the P3-Roc can be used in two ways in MPF.

  • Burst Optos - As burst switch inputs in combination with a burst switcher driver can drive long-beam optos. This is how they were originally intended.
  • Local Inputs - Alternatively you can use them as direct local inputs (and the burst drivers as outputs; see How to configure coils/drivers/magnets (P-ROC/P3-ROC) section for details).
../../_images/multimorphic_p3_roc.png

Burst Switches as Burst Optos

You can configure burst optos using the following syntax:

switches:
  burst_opto_1_20:
    number: burst-1-20     # burst input with switch 1 and driver 20
  burst_opto_2_20:
    number: burst-2-20     # burst input with switch 2 and driver 20
  burst_opto_10_5:
    number: burst-10-5     # burst input with switch 10 and driver 5
This example is tested to be valid MPF config. However, it is not integration tested.
switches:
  burst_opto_1_20:
    number: burst-1-20     # burst input with switch 1 and driver 20
  burst_opto_2_20:
    number: burst-2-20     # burst input with switch 2 and driver 20
  burst_opto_10_5:
    number: burst-10-5     # burst input with switch 10 and driver 5

Make sure to disable DIP switches 1 and 2 on the P3-Roc. You can configure up to five switches per driver.

Note

There is currently no reliable way to read the initial state of burst optos. MPF will assume that all burst IRs are open on start-up. This might cause if you use it to track balls in a ball lock which might contain balls from a previous game. This limitation will probably go away in future firmware update of the P3-Roc.

Burst Opto PCBs

Burst optos are unlike normal optos and you cannot use normal optos. Instead, they use 40kHz infrared transmitters and receivers. Multimorphic sells them as single transmitter/receiver (part number: PCBA-0011-0002) and as bank of 8 (part number: PCBA-0003-0003).

Burst Switches as Local Inputs

If you want to use burst switches as local inputs set DIP switch 2 to on on the P3-Roc. You can use those 64 inputs as direct inputs:

switches:
  local_switch0:
    number: direct-0       # local input 0
  local_switch20:
    number: direct-20      # local input 20
This example is tested to be valid MPF config. However, it is not integration tested.
switches:
  local_switch0:
    number: direct-0       # local input 0
  local_switch20:
    number: direct-20      # local input 20

Make sure to assign IDs >= 4 to all SW-16 boards if you set DIP 2. Local switches behave just like any other switch on the P3-Roc. Hardware rules, debouncing etc. will behave exactly the same way.

Note

You need at least Firmware version 2.6 to use burst switches as local inputs on the P3-Roc.

Warning

There is no electronic protection on the P3-Roc for burst switches (neither as local inputs nor as burst optos). Do not use them without additional protection. Any voltage above 3.3V or below 0V will irreversibly damage the P3-Roc. Make sure you know what you are doing before turning this on. We advise to use SW-16 for normal playfield/mech inputs and only use local inputs with additional circuits (not directly). If you plan to use burst optos have a look at the PCBs offered from Multimorphic for that purpose.

Debounce options

The P-ROC has the ability to configure debounce settings for switches. A non-debounced switch which report its state change immediately, while a debounced switch will report its state change after it’s been in the new state for two consecutive reads.

By default, MPF will enable debouncing in both directions (open and close) for all switches. However you can override this on a per-switch basis with a switch’s debounce: setting.

Valid options are normal, quick, and auto.

To disable debouncing for a switch, add debounce: quick to the switch config, like this:

switches:
  my_switch:
    number: A0-B0-0
    debounce: quick
This example is tested to be valid MPF config. However, it is not integration tested.
switches:
  my_switch:
    number: A0-B0-0
    debounce: quick

To force debouncing to always be used (which is also the default on the P-ROC, so not really needed), configure it like this:

switches:
  my_switch:
    number: A0-B0-0
    debounce: normal
This example is tested to be valid MPF config. However, it is not integration tested.
switches:
  my_switch:
    number: A0-B0-0
    debounce: normal

What if it did not work?